Industrial thermal imaging camera
The FLIR A615 is an easy-to-use, affordable, compact thermal imaging camera for condition monitoring, process control/quality assurance and fire protection. The camera is fully PC controllable and, thanks to its standards compliance, plug-and-play compatible with software packages from National Instruments, Cognex, Matrox, MVtec and Stemmer Imaging.
VERY HIGH IMAGE QUALITY
- Equipped with a 640 x 480 pixel microbolometer, the FLIR A615 can detect temperature differences of up to 50 mK, ensuring accuracy at longer distances
LINEAR TEMPERATURE OUTPUT WITH 16-BIT
- Thanks to the linear 16-bit temperature output, non-contact temperature measurement can be performed with any third-party software.
STREAMING IN HIGH FREQUENCY RANGE
- Stream full 16-bit images at 50 Hz or up to 200 Hz in blanking mode for high-speed processing.
Track temperature changes, stream radiometric images
The FLIR A615 produces high-quality infrared images with a resolution of 307,200 pixels and has built-in temperature measurement, so you can measure any point in the target area up to 2000 °C.
TECHNICAL DATA
- Digital inputs: 2 via optocouplers, 10-30 V DC
- Purpose digital output: output to external device (is written program-controlled)
- Digital outputs: 2 via optocouplers, 10-30 V DC, max. 100 mA
- EMC: EN 61000-6-2:2001 (immunity), EN 61000-6-3:2001 (radiation), FCC 47 CFR part 15 class B (radiation)
- F-number: 1.0
- Frame rate: 50 Hz (100/200 Hz with windowing)
- Thermal sensitivity / NETD: < 0.05 °C at +30 °C/50 mK
- Accuracy: ±2 °C or ±2 % of measured value
COMMUNICATION AND DATA STORAGE
- Digital outputs: 2 via optocouplers, 10-30 V DC, max. 100 mA
- Digital inputs: 2 via optocouplers, 10-30 V DC
- Ethernet: Control and image
- Ethernet image streaming: 16-bit 640 x 480 pixels at 50 Hz, 16-bit 640 x 240 pixels at 100 Hz, 16-bit 640 x 120 pixels at 200 Hz (Signal linear, Temperature linear, Radiometric Compatible with GigE Vision and GenICam)
- Ethernet communication: Based on FLIR proprietary TCP/IP socket and GenICam protocol
- Ethernet protocols: TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
- Ethernet standard: IEEE 802.3
- Ethernet type: Gigabit Ethernet
- USB: control and image
- USB - image streaming: 16-bit 640 × 480
- USB - Communication: Based on a TCP/IP socket, proprietary to FLIR
- USB - Standard: USB 2 HS
- USB - Protocols: TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
- USB - connector type: USB Mini-B
- Purpose digital output: output to external device (is written programmatically)
- Purpose digital input: image marker (start/stop/general), image sequencer (stream ON/OFF), input to external device (is read programmatically)
IMAGING AND OPTICAL DATA
- Frame rate: 30 Hz
- F-number: 1.25
- Focal length: 25 mm
- Detector pitch: 17 µm
- detector type: focal plane array (FPA), uncooled VOX microbolometer
- Detector time constant: normally 12 ms
- FLIR Screen-EST Mode: No
- Focus: Fixed
- IR Resolution: 640 x 512 Pixel
- Spatial resolution (IFOV): 0.68 mrad
- Field of View (FOV): 25° x 20° with 25 mm lens
- Spectral range: 7.5 - 13 µm
- Thermal sensitivity / NETD: < 0.05 °C at 30 °C/50 mK
MEASUREMENT AND ANALYSIS
- Equivalent temperature correction: Automatic, based on the reflected temperature input.
- Emissivity correction: Variable from 0.5 to 1.0
- Accuracy: ±5 °C or ±5 % of measured value
- Camera dimensions (L × W × H): 106 mm x 47 mm x 50 mm
- Atmospheric transmittance correction: Automatic, based on distance, atmospheric temperature, and relative humidity data
- Optics transmittance correction: Automatic, based on signals from internal sensors
- External optics/windows correction: Automatic, based on input of transmittance of respective optics/windows and temperature
- Measurement corrections: Global object parameters
- Object temperature range: -25 °C to 135 °C/-40 °C to 550 °C
GENERAL INFORMATION
- Housing material: magnesium and aluminum
- Weight: 0.21 kg
- Base mounting: 4 x M3 threaded holes (bottom)
ENVIRONMENTAL FACTORS AND CERTIFICATIONS
- Operating temperature range: -15 °C to +50 °C
- EMC: EN 61000-6-2:2001 (immunity), EN 61000-6-3:2001 (radiation), FCC 47 CFR Part 15 Class B (radiation)
- Housing: IP 30 (IEC 60529)
- Storage temperature range: -40 °C to +70 °C
- Humidity (operation and storage): IEC 60068-2-30/24 h 95 % relative humidity +25 °C to +40 °C
- Shock resistance: 25 g (IEC 60068-2-27)
- Vibration: 2 g (IEC 60068-2-6)
POWER SUPPLY
- Operation with external power supply: 12/24 V DC, < 3.5 W nominal value < 6.0 W absolute maximum value
- Voltage: Permissible measuring range 10 - 30 V DC
Scope of delivery:
- 1x hard shell transport case or cardboard packaging
- 1x FLIR infrared camera with lens
- 1x CD-ROM with utilities
- 1x calibration certificate
- 1x Ethernet™ cable
- 1x USB cable (FLIR A615)
- 1x power cable
- 1x power cable (with connecting lead)
- 1x power supply unit
- 1x printed quick start guide
- 1x summary of important information (printed)
- 1x CD-ROM with user documentation
- 1x warranty extension card or registration card
- 1x 6-pin screw terminal (mounted on the camera)