FLIR AX5 Series Cameras

Item number: MBS-FLIR-01

FLIR AX5 Series Cameras

  • GigE Vision and GenICam compliance
  • Size 4.1 × 1.9 × 1.8 in.
  • synchronization between multiple cameras possible
  • also for stereoscopic applications

Category: Sensors

Model
FOV

starting from 5.711,00 €

including 19% VAT. , plus shipping

Available now!

There are variations of this item. Please select the variation you wish.


The FLIR Ax5 series consists of thermal imagers for condition monitoring, process control/quality assurance and fire protection. The cameras integrate seamlessly into existing systems and provide comprehensive visual temperature monitoring. The Ax5 Series is among the only thermal imaging sensors on the market with linear temperature output using GenICam™ compliant software.

 

FLIR A65

INEXPENSIVE AND COMPACT

  • At just 4.1 × 1.9 × 1.8 inches, the A65 produces thermal images in a small space at an affordable price.

PLUG-AND-PLAY

  • GigE Vision and GenICam compliance and a lockable GigE Vision connector make the camera easy to set up.

CONNECTION OF MULTIPLE CAMERAS

  • Synchronization between multiple cameras for greater coverage and communication or for stereoscopic applications.

The advantage of temperature measurement over image quality

The FLIR A65 produces stunning 327,680 pixel thermal images that are low noise and can show temperature differences as small as 50 mK. This makes it easy to track temperature changes, whether in process control/quality assurance, condition monitoring or fire protection applications.

 

TECHNICAL DATA

  • Digital inputs: 1× opto-isolated, "0" <1.2 V DC, "1" = 2-25 V DC.
  • Purpose digital output: universal output for ext. device (programmed).
  • Digital outputs: 1x opto-isolated, 2 - 40 V DC, max. 185 mA
  • EMC: EN 61000-6-2 (immunity) EN 61000-6-3 (radiation) FCC 47 CFR part 15 class B (radiation)
  • F-number: 1.25
  • Frame rate: 30 Hz
  • Thermal sensitivity / NETD: < 0.05 °C at 30 °C/50 mK
  • Accuracy: ±5 °C or ±5 % of reading

COMMUNICATION AND DATA STORAGE

  • Digital outputs: 1x opto-isolated, 2 - 40 V DC, max. 185 mA.
  • Digital inputs: 1× opto-isolated, "0" <1.2 V DC, "1" = 2-25 V DC.
  • Ethernet: Control and image
  • Ethernet image streaming: 8-bit monochrome at 60 Hz signal linear/ DDE auto/manual rotation H&V 14-bit 320 x 256 pixels at 60 Hz signal linear/ DDE temperature linear GigE Vision and GenICam compatible
  • Ethernet communication: GigE Vision Vers. 1.2 Client API GenICam compatible
  • Ethernet protocols: TCP, UDP, ICMP, IGMP, DHCP, GigEVision
  • Ethernet standard: IEEE 802.3/RJ-45
  • Ethernet power supply: Power over Ethernet, PoE IEEE 802.3af class 0
  • Ethernet type: Gigabit Ethernet
  • Synchronization output: 1x, not decoupled
  • Synchronization output - type: LVC buffer at 3.3 V, "0"=24 MA max, "1"= -24 mA max.
  • Synchronization output - Usage: Image synchronization output to control another Ax5 camera.
  • Synchronization input: 1x, not decoupled
  • Sync input - type: LVC buffer at 3.3 V, "0" <0.8 V, "1" >2.0 V.
  • Synchronization input - Usage: Image synchronization input for camera control.
  • Purpose digital output: universal output for ext. device (programmed)
  • Purpose digital input: Universal

IMAGING AND OPTICAL DATA

  • Bildfrequenz: 30 Hz
  • Blendenzahl: 1,25
  • Brennweite: 25 mm
  • Detektorraster: 17 µm
  • Detektortyp: Focal Plane Array (FPA), ungekühlter VOX-Mikrobolometer
  • Detektor-Zeitkonstante: normalerweise 12 ms
  • FLIR Screen-EST Mode: No
  • Fokus: Fest
  • IR-Auflösung: 640 x 512 Pixel
  • Räumliche Auflösung (IFOV): 0,68 mrad
  • Sichtfeld (FOV): 25° x 20° mit 25-mm-Objektiv
  • Spektralbereich: 7,5 - 13 µm
  • Thermische Empfindlichkeit / NETD: < 0,05 °C bei 30 °C/50 mK

MEASUREMENT AND ANALYSIS

  • Equivalent temperature correction: Automatic, based on the reflected temperature input.
  • Emissivity correction: Variable from 0.5 to 1.0
  • Accuracy: ±5 °C or ±5 % of measured value
  • Camera dimensions (L × W × H): 106 mm x 47 mm x 50 mm
  • Atmospheric transmittance correction: Automatic, based on distance, atmospheric temperature, and relative humidity data
  • Optics transmittance correction: Automatic, based on signals from internal sensors
  • External optics/windows correction: Automatic, based on input of transmittance of respective optics/windows and temperature
  • Measurement corrections: Global object parameters
  • Object temperature range: -25 °C to 135 °C/-40 °C to 550 °C

GENERAL INFORMATION

  • Housing material: magnesium and aluminum
  • Weight: 0.21 kg
  • Package contents: Packing box, thermal imaging camera with lens, focus adjustment tool, printed user documentation, user documentation on CD-ROM, FLIR Tools download card
  • Base mounting: 4 x M3 threaded holes (bottom)

ENVIRONMENTAL FACTORS AND CERTIFICATIONS

  • Operating temperature range: -15 °C to 50 °C The operating temperature range assumes that the camera is mounted on the base plate (included in the package) or on a comparable heat sink.
  • Housing: IP 40 (IEC 60529) with base plate mounted
  • Storage temperature range: -40 °C to 70 °C
  • Humidity (operation and storage): IEC 60068-2-30/24 hr 95% relative humidity 25 °C to 40 °C
  • Tripod mounting: UNC ¼ inch -20 (on three sides)
  • Shock resistance: 25 g (IEC 60068-2-27)
  • Vibration: 2 g (IEC 60068-2-6 and MIL-STD810G)

POWER SUPPLY

Operation with external power supply: 12/24 V DC, < 3.5 W nominal value < 6.0 W absolute maximum value
Voltage: Permissible measuring range 10 - 30 V DC

Scope of delivery:

  • 1x FLIR AX5 series camera
  • 1x lens
  • Cable ties (2 each)
  • Tool for focus adjustment
  • 1x Printed user documentation
  • User documentation on CD-ROM
  • FLIR Tools download card

 

FLIR A35

INEXPENSIVE AND COMPACT

  • At just 4.1 × 1.9 × 1.8 inches, the A65 produces thermal images in a small space at an affordable price.

PLUG-AND-PLAY

  • GigE Vision and GenICam compliance and a lockable GigE Vision connector make the camera easy to set up.

CONNECTION OF MULTIPLE CAMERAS

  • Synchronization between multiple cameras for greater coverage and communication or for stereoscopic applications.

The advantage of temperature measurement over image quality

The FLIR A35 produces high quality 81,920 pixel thermal images that can show temperature differences of up to 50 mK. This makes it easy to track temperature changes, whether the application is process control/quality assurance, condition monitoring or fire protection.

 

TECHNICAL DATA

  • Digital inputs: Universal, 1× opto-isolated, "0" <1.2 V DC, "1" = 2-25 V DC.
  • Purpose Digital output: Universal output for ext. device (programmed).
  • Digital outputs: 1x opto-isolated, 2 - 40 V DC, max. 185 mA
  • EMC: -EN 61000-6-2 (immunity) -EN 61000-6-3 (radiation) -FCC 47 CFR part 15 class B (radiation)
  • F-number: 1.25
  • Frame rate: 60 Hz
  • Thermal sensitivity / NETD: < 0.05 °C at 30 °C/50 mK
  • Accuracy: ±5 °C or ±5 % of reading

COMMUNICATION AND DATA STORAGE

  • Digital outputs: 1x opto-isolated, 2 - 40 V DC, max. 185 mA.
  • Digital inputs: universal, 1× opto-isolated, "0" <1.2 V DC, "1" = 2-25 V DC.
  • Ethernet: Control and image
  • Ethernet image streaming: 8-bit monochrome at 60 Hz signal linear/ DDE auto/manual rotation H&V 14-bit 320 x 256 pixels at 60 Hz signal linear/ DDE temperature linear GigE Vision and GenICam compatible
  • Ethernet communication: GigE Vision Vers. 1.2 Client API GenICam compatible
  • Ethernet protocol: IEEE 802.3
  • Ethernet power supply: Power over Ethernet, PoE IEEE 802.3af Class 0
  • Ethernet type: Gigabit Ethernet
  • Synchronization output: 1x, not decoupled
  • Synchronization output - type: LVC buffer at 3.3 V, "0"=24 MA max, "1"= -24 mA max.
  • Synchronization output - Usage: Image synchronization output to control another Ax5 camera.
  • Synchronization input: 1x, not decoupled
  • Sync input - type: LVC buffer at 3.3 V, "0" <0.8 V, "1" >2.0 V.
  • Synchronization input - Usage: Image synchronization input for camera control.
  • Purpose digital output: universal output for ext. device (programmed).

IMAGING AND OPTICAL DATA

  • Frame rate: 60 Hz
  • F-number: 1.25
  • Focal length: 9 mm
  • Detector pitch: 25 µm
  • detector type: focal plane array (FPA), uncooled VOX microbolometer
  • Detector time constant: normally 12 ms
  • FLIR Screen-EST Mode: No
  • Focus: Fixed
  • IR Resolution: 320 x 256 Pixel
  • Spatial resolution (IFOV): 2.78 mrad
  • Field of View (FOV): 48° x 39
  • Spectral Range: 7.5 - 13 µm
  • Thermal sensitivity / NETD: < 0.05 °C at 30 °C/50 mK

MEASUREMENT AND ANALYSIS

  • Equivalent temperature correction: Automatic, based on the reflected temperature input.
  • Emissivity correction: Variable from 0.5 to 1.0
  • Accuracy: ±5 °C or ±5 % of measured value
  • Camera dimensions (L × W × H): 106 × 40 × 43 mm
  • Atmospheric transmittance correction: Automatic, based on distance, atmospheric temperature, and relative humidity data
  • Optics transmittance correction: Automatic, based on signals from internal sensors
  • Measurement corrections: Global object parameters
  • Object temperature range: -25 °C to 135 °C/-40 °C to 550 °C

GENERAL INFORMATION

  • Housing material: magnesium and aluminum
  • Weight: 0.200 kg
  • Base mounting: 4 x M3 threaded holes (bottom)
  • Package size: 370 x 180 x 320 mm

ENVIRONMENTAL FACTORS AND CERTIFICATIONS

  • Operating temperature range: -15 °C to +50 °C The operating temperature range assumes that the camera is mounted on the base plate (included in the package) or on a comparable heat sink.
  • Housing: IP 40 (IEC 60529) with base plate mounted
  • Storage temperature range: -40 °C to 70 °C
  • Humidity (operation and storage): IEC 60068-2-30/24 hr 95% relative humidity 25 °C to 40 °C
  • Tripod mounting: UNC ¼ inch -20 (on three sides)
  • Shock resistance: 25 g (IEC 60068-2-27)
  • Vibration: 2 g (IEC 60068-2-6 u. MIL-STD810G)

POWER SUPPLY

  • Operation with external power supply: 12/24 V DC, < 3.5 W nominal value < 6.0 W absolute maximum value
  • Voltage: Permissible measuring range 10 - 30 V DC

 

Scope of delivery:

  • 1x FLIR Kamera der AX5 Serie
  • 1x Objektiv
  • 1x Hartschalen-Schutzkoffer
  • Kabelbinder (jeweils 2)
  • Ethernetkabel CAT-6, 2 m (jeweils 2)
  • 1x FLIR ResearchIR Standard 4 Fokus-Justierungshilfe
  • 1x Schwanenhals
  • 1x Netzkabelsatz (UK, EU, US)
  • 1x PoE-Injektor (Power over Ethernet)
  • 1x Gedruckte Benutzerdokumentation
  • 1x Tischständer

 

 


Shipping weight: 0,60 Kg
Product weight: 0,20 Kg
Average product review

Write your first review and help others with their purchase decision: